China New Product Dr Trust Portable Nebulizer - ACCUGENCE ® Multi-Monitoring System (PM 800) – e-Linkcare
China New Product Dr Trust Portable Nebulizer - ACCUGENCE ® Multi-Monitoring System (PM 800) – e-Linkcare Detail:
|
Feature |
Specification |
|
Parameter |
Blood Glucose, Blood β-Ketone, and Blood Uric Acid |
| Measurement Range |
Blood Glucose: 0.6 – 33.3 mmol/L (10 – 600 mg/dL) |
|
Blood β-Ketone: 0.0 – 8.0 mmol/L |
|
|
Uric Acid: 3.0 – 20.0 mg/dL (179 – 1190 μmol/L) |
|
|
Hemoglobin: 3.0-26.0 g/dL (1.9-16.1mmol/L) |
|
|
Hematocrit Range |
Blood Glucose and β-Ketone: 15% – 70 % |
|
Uric Acid: 25% – 60% |
|
|
Sample |
When testing β-Ketone, Uric Acid or Blood glucose with Glucose Dehydrogenase FAD-Dependent, use fresh capillary whole blood and venous Blood samples; |
|
When testing Blood glucose with Glucose Oxidase: use fresh capillary whole blood |
|
|
Minimum Sample Size |
Hemoglobin: 1.2 μL |
|
Blood Glucose: 0.7 μL |
|
|
Blood β-Ketone: 0.9 μL |
|
|
Blood Uric Acid: 1.0 μL |
|
|
Test Time |
Hemoglobin: 15 seconds |
|
Blood Glucose: 5 seconds |
|
|
Blood β-Ketone: 5 seconds |
|
|
Blood Uric Acid: 15 seconds |
|
|
Units of Measure |
Blood Glucose: The meter is preset to either millimole per liter (mmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
|
Blood β-Ketone: The meter is preset to millimole per liter (mmol/L) |
|
|
Blood Uric Acid: The meter is preset to either micromole per liter (μmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
|
| Hemoglobin: the meter is preset to either to millimole per liter (mmol/L) or grams per deciliter (g/dL) depending on the standard of your country. | |
|
Memory |
Hemoglobin: 200 tests |
|
Blood Glucose: 500 tests (GOD + GDH) |
|
|
Blood β-Ketone: 100 tests |
|
|
Blood Uric Acid: 100 tests |
|
|
Automatic Shutoff |
2 minutes |
|
Meter Size |
86 mm × 52 mm × 18 mm |
|
On/Off Source |
Two CR 2032 3.0V coin cell batteries |
|
Battery Life |
Around 1000 tests |
|
Display Size |
32 mm × 40 mm |
|
Weight |
53 g (with battery installed) |
|
Operating Temperature |
Glucose and Ketone: 5 – 45 ºC (41 – 113ºF) |
|
Uric Acid: 10 – 40 ºC (50 – 104ºF) |
|
|
Operating Relative Humidity |
10 – 90% (non-condensing) |
|
Operating Altitude |
0 – 10000 feet (0 – 3048 meters) |
Product detail pictures:
Related Product Guide:
Our development depends on the advanced equipment, excellent talents and continuously strengthened technology forces for China New Product Dr Trust Portable Nebulizer - ACCUGENCE ® Multi-Monitoring System (PM 800) – e-Linkcare , The product will supply to all over the world, such as: Albania, Austria, Austria, It is our customers' satisfaction over our products and services that always inspires us to do better in this business. We build mutually beneficial relationship with our clients by giving them large selection of premium car parts at marked down prices. We provide wholesale prices on all our quality parts so you are guaranteed greater savings.