Feature |
Specification |
|
Parameter |
Blood Glucose, Blood β-Ketone, and Blood Uric Acid |
| Measurement Range |
Blood Glucose: 0.6 – 33.3 mmol/L (10 – 600 mg/dL) |
|
Blood β-Ketone: 0.0 – 8.0 mmol/L |
|
|
Uric Acid: 3.0 – 20.0 mg/dL (179 – 1190 μmol/L) |
|
|
Hemoglobin: 3.0-26.0 g/dL (1.9-16.1mmol/L) |
|
|
Hematocrit Range |
Blood Glucose and β-Ketone: 15% – 70 % |
|
Uric Acid: 25% – 60% |
|
|
Sample |
When testing β-Ketone, Uric Acid or Blood glucose with Glucose Dehydrogenase FAD-Dependent, use fresh capillary whole blood and venous Blood samples; |
|
When testing Blood glucose with Glucose Oxidase: use fresh capillary whole blood |
|
|
Minimum Sample Size |
Hemoglobin: 1.2 μL |
|
Blood Glucose: 0.7 μL |
|
|
Blood β-Ketone: 0.9 μL |
|
|
Blood Uric Acid: 1.0 μL |
|
|
Test Time |
Hemoglobin: 15 seconds |
|
Blood Glucose: 5 seconds |
|
|
Blood β-Ketone: 5 seconds |
|
|
Blood Uric Acid: 15 seconds |
|
|
Units of Measure |
Blood Glucose: The meter is preset to either millimole per liter (mmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
|
Blood β-Ketone: The meter is preset to millimole per liter (mmol/L) |
|
|
Blood Uric Acid: The meter is preset to either micromole per liter (μmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
|
| Hemoglobin: the meter is preset to either to millimole per liter (mmol/L) or grams per deciliter (g/dL) depending on the standard of your country. | |
|
Memory |
Hemoglobin: 200 tests |
|
Blood Glucose: 500 tests (GOD + GDH) |
|
|
Blood β-Ketone: 100 tests |
|
|
Blood Uric Acid: 100 tests |
|
|
Automatic Shutoff |
2 minutes |
|
Meter Size |
86 mm × 52 mm × 18 mm |
|
On/Off Source |
Two CR 2032 3.0V coin cell batteries |
|
Battery Life |
Around 1000 tests |
|
Display Size |
32 mm × 40 mm |
|
Weight |
53 g (with battery installed) |
|
Operating Temperature |
Glucose and Ketone: 5 – 45 ºC (41 – 113ºF) |
|
Uric Acid: 10 – 40 ºC (50 – 104ºF) |
|
|
Operating Relative Humidity |
10 – 90% (non-condensing) |
|
Operating Altitude |
0 – 10000 feet (0 – 3048 meters) |
Product detail pictures:
Related Product Guide:
We pursue the management tenet of "Quality is remarkable, Company is supreme, Name is first", and will sincerely create and share success with all clientele for Chinese Professional Yuwell Ultrasonic Nebulizer - ACCUGENCE ® Multi-Monitoring System (PM 800) – e-Linkcare , The product will supply to all over the world, such as: South Africa, Spain, Guatemala, Our business activities and processes are engineered to make sure our customers have access to widest range of products with the shortest supply time lines. This achievement is made possible by our highly skilled and experienced team. We look for people who want to grow with us around the globe and stand out from the crowd. We now have people who embrace tomorrow, have vision, love stretching their minds and going far beyond what they thought was achievable.