factory customized Blood Sugar Control - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare
factory customized Blood Sugar Control - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare Detail:
Features:
Chronic airway inflammation is a general feature of some types of asthma, cystic fibrosis (CF), bronchopulmonary dysplasia (BPD), and chronic obstructive pulmonary disease (COPD).
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.
Fractional concentration of carbon monoxide in exhaled breath (FeCO), similar to FeNO, has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs.
UBREATH Exhalation analyzer (BA810) is a medical device designed & manufactured by e-LinkCare Meditech to associate with both FeNO and FeCO testing to provide rapid, precise, quantitative measurement in order to assist with clinical diagnosis and management such as asthma and other chonic airway inflammations.
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.
| ITEM | Measurement | Reference |
| FeNO50 | Fixed Exhale flow level of 50ml/s | 5-15ppb |
| FeNO200 | Fixed Exhale flow level of 200ml/s | <10 ppb |
In the meantime, BA200 also provides data for the following parameters
| ITEM | Measurement | Reference |
| CaNO | Concentration of NO in the gas phase of the alveolar | <5 ppb |
| FnNO | Nasal nitric oxide | 250-500 ppb |
| FeCO | Fractional concentration of carbon monoxide in exhaled breath | 1-4ppm>6 ppm (if smoking) |
Product detail pictures:
Related Product Guide:
"Based on domestic market and expand overseas business" is our development strategy for factory customized Blood Sugar Control - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare , The product will supply to all over the world, such as: Los Angeles, Casablanca, Yemen, We adopted technique and quality system management, based on "customer orientated, reputation first, mutual benefit, develop with joint efforts", welcome friends to communicate and cooperate from all over the world.