factory customized Blood Sugar Control - UBREATH ® Spirometer System (PF680) – e-Linkcare

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have many excellent staff members good at marketing, QC, and dealing with kinds of troublesome problem in the production process for One Drop Glucometer , 109 Fasting Blood Sugar , No Blood Glucose Meter , And there are also a lot of overseas close friends who came for sight seeing, or entrust us to buy other stuff for them. You will be most welcome to come to China, to our city and to our manufacturing facility!
factory customized Blood Sugar Control - UBREATH ® Spirometer System (PF680) – e-Linkcare Detail:

Measurable Spirometry through Inhale & Exhale
FVC, SVC, MVV are available with 23 parameters to be calculated.
Accuracy and repeatability comply with ATS/ERS task force standardization (ISO26782:2009)
Complies with the ATS/ERS requirement for flow sensitivity down to 0.025L/s which is a vital characteristic for the diagnosis and monitoring of COPD patients.

Real-time Graphic Curve Experience
Synchronized graphs enhance users to achieve satisfied results with professional’s guidance.
Displayed three waveform parameters and remark the best performance for reference.

Portable Design
Hand-held device and easy to operation.
Automated BTPS calibration and free of environmental conditions influence.
Lightweight combines the benefits of portability.

Operate with Safety
Assured hygiene with disposable pneumotach gives NO authority to cross-contamination.
Patented design offers prevention and no daily sterilization is required.
Automated quality control and correction algorithm to minimize interference from operation.

All-in-One Service Station
Built-in printer and barcode scanner are combined in one device.
LIS/HIS connection via Wi-Fi and HL7.

Technical Specifications

Feature Specification
Model PF680
Parameter FVC: FVC, FEV1, FEV1%, PEF, FEF25, FEF50, FEF75VC: VC, VT, IRV, ERV, IC
MVV: MVV, VT, RR
Flow Detection Principle Pneumotachograph
Volume Range Volume: (0.5-8) LFlow: (0-14) L/s
Performance Standard ATS/ERS 2005 & ISO 26783:2009
Volume Accuracy ±3% or ±0.050L (take the larger value)
Power Supply 3.7 V lithium battery (rechargeable)
Printer Built-in thermal printer
Operating Temperature 10℃ - 40℃
Operating Relative Humidity ≤ 80%
Size Spirometer: 133x82x68 mmSensor Handle: 82x59x33 mm
Weight 575g (including the Flow Transducer)

Product detail pictures:

factory customized Blood Sugar Control - UBREATH ® Spirometer System (PF680) – e-Linkcare detail pictures


Related Product Guide:

Every single member from our higher effectiveness product sales staff values customers' requires and organization communication for factory customized Blood Sugar Control - UBREATH ® Spirometer System (PF680) – e-Linkcare , The product will supply to all over the world, such as: Malta, Sao Paulo, Czech republic, With the growing of the company, now our products sold and served at more than 15 countries around the world,such as Europe,North America,Middle-east,South America,Southern Asia and so on. As we bear in our mind that innovation is essential to our growth, new product development is constantly.Besides, Our flexible and efficient operation strategies,High quality products and competitive prices are exactly what our customers are looking for. Also a considerable service brings us good credit reputation.
  • The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Carol from Gambia - 2017.12.19 11:10
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Dorothy from Hongkong - 2018.07.12 12:19
    CONTACT US
    Write your message here and send it to us