factory Outlets for Capillary Blood Glucose - UBREATH ® Spirometer System (PF680) – e-Linkcare

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have many excellent staff members good at marketing, QC, and dealing with kinds of troublesome problem in the production process for Blood Uric Acid , Prickless Blood Sugar Monitor , Sugar Level Monitor , Living by good quality, enhancement by credit history is our eternal pursuit, We firmly feel that soon after your visit we will become long-term associates.
factory Outlets for Capillary Blood Glucose - UBREATH ® Spirometer System (PF680) – e-Linkcare Detail:

Measurable Spirometry through Inhale & Exhale
FVC, SVC, MVV are available with 23 parameters to be calculated.
Accuracy and repeatability comply with ATS/ERS task force standardization (ISO26782:2009)
Complies with the ATS/ERS requirement for flow sensitivity down to 0.025L/s which is a vital characteristic for the diagnosis and monitoring of COPD patients.

Real-time Graphic Curve Experience
Synchronized graphs enhance users to achieve satisfied results with professional’s guidance.
Displayed three waveform parameters and remark the best performance for reference.

Portable Design
Hand-held device and easy to operation.
Automated BTPS calibration and free of environmental conditions influence.
Lightweight combines the benefits of portability.

Operate with Safety
Assured hygiene with disposable pneumotach gives NO authority to cross-contamination.
Patented design offers prevention and no daily sterilization is required.
Automated quality control and correction algorithm to minimize interference from operation.

All-in-One Service Station
Built-in printer and barcode scanner are combined in one device.
LIS/HIS connection via Wi-Fi and HL7.

Technical Specifications

Feature Specification
Model PF680
Parameter FVC: FVC, FEV1, FEV1%, PEF, FEF25, FEF50, FEF75VC: VC, VT, IRV, ERV, IC
MVV: MVV, VT, RR
Flow Detection Principle Pneumotachograph
Volume Range Volume: (0.5-8) LFlow: (0-14) L/s
Performance Standard ATS/ERS 2005 & ISO 26783:2009
Volume Accuracy ±3% or ±0.050L (take the larger value)
Power Supply 3.7 V lithium battery (rechargeable)
Printer Built-in thermal printer
Operating Temperature 10℃ - 40℃
Operating Relative Humidity ≤ 80%
Size Spirometer: 133x82x68 mmSensor Handle: 82x59x33 mm
Weight 575g (including the Flow Transducer)

Product detail pictures:

factory Outlets for Capillary Blood Glucose - UBREATH ® Spirometer System (PF680) – e-Linkcare detail pictures


Related Product Guide:

We emphasize advancement and introduce new products and solutions into the market each year for factory Outlets for Capillary Blood Glucose - UBREATH ® Spirometer System (PF680) – e-Linkcare , The product will supply to all over the world, such as: Philadelphia, Greece, Belarus, With the aim of "compete with good quality and develop with creativity" and the service principle of "take customers' demand as orientation", we will earnestly provide qualified products and solutions and good service for domestic and international customers.
  • Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Marjorie from Curacao - 2017.12.31 14:53
    The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By Lindsay from Luxemburg - 2017.10.23 10:29
    Write your message here and send it to us