We believe in: Innovation is our soul and spirit. Quality is our life. Customer need is our God for Sugar Level Check Machine , Blood Sugar Over 1000 , Blood Sugar Monitor , The principle of our company is to provide high-quality products, professional service, and honest communication. Welcome all friends to place trial order for creating a long-term business relationship.
Factory wholesale Blood Glucose Reader - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare Detail:

Features:

Chronic airway inflammation is a general feature of some types of asthma, cystic fibrosis (CF), bronchopulmonary dysplasia (BPD), and chronic obstructive pulmonary disease (COPD).
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

Fractional concentration of carbon monoxide in exhaled breath (FeCO), similar to FeNO, has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs.

UBREATH Exhalation analyzer (BA810) is a medical device designed & manufactured by e-LinkCare Meditech to associate with both FeNO and FeCO testing to provide rapid, precise, quantitative measurement in order to assist with clinical diagnosis and management such as asthma and other chonic airway inflammations.

In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

ITEM Measurement Reference
FeNO50  Fixed Exhale flow level of 50ml/s 5-15ppb
FeNO200  Fixed Exhale flow level of 200ml/s <10 ppb

In the meantime, BA200 also provides data for the following parameters

ITEM Measurement Reference
CaNO Concentration of NO in the gas phase of the alveolar <5 ppb
FnNO Nasal nitric oxide 250-500 ppb
FeCO Fractional concentration of carbon monoxide in exhaled breath 1-4ppm>6 ppm (if smoking)

Product detail pictures:

Factory wholesale Blood Glucose Reader - UBREATH ® Exhalation analyzer (BA200)  – e-Linkcare detail pictures


Related Product Guide:

We always continually provide you with the most conscientious customer service, and the widest variety of designs and styles with finest materials. These efforts include the availability of customized designs with speed and dispatch for Factory wholesale Blood Glucose Reader - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare , The product will supply to all over the world, such as: Berlin, Armenia, Juventus, We have now a good reputation for stable quality goods, well received by customers at home and abroad. Our company would be guided by the idea of "Standing in Domestic Markets, Walking into International Markets". We sincerely hope that we could do business with car manufacturers, auto part buyers and the majority of colleagues both at home and abroad. We expect sincere cooperation and common development!
  • We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Martha from Germany - 2017.11.29 11:09
    We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Elsa from kazakhstan - 2018.12.10 19:03
    Write your message here and send it to us