High Quality for Diabetic Patient Management System - UBREATH ® Spirometer System (PF680) – e-Linkcare
High Quality for Diabetic Patient Management System - UBREATH ® Spirometer System (PF680) – e-Linkcare Detail:

Measurable Spirometry through Inhale & Exhale
FVC, SVC, MVV are available with 23 parameters to be calculated.
Accuracy and repeatability comply with ATS/ERS task force standardization (ISO26782:2009)
Complies with the ATS/ERS requirement for flow sensitivity down to 0.025L/s which is a vital characteristic for the diagnosis and monitoring of COPD patients.
Real-time Graphic Curve Experience
Synchronized graphs enhance users to achieve satisfied results with professional’s guidance.
Displayed three waveform parameters and remark the best performance for reference.
Portable Design
Hand-held device and easy to operation.
Automated BTPS calibration and free of environmental conditions influence.
Lightweight combines the benefits of portability.
Operate with Safety
Assured hygiene with disposable pneumotach gives NO authority to cross-contamination.
Patented design offers prevention.
Automated quality control and correction algorithm to minimize interference from operation.
All-in-One Service Station
Built-in printer and barcode scanner are combined in one device.
LIS/HIS connection via Wi-Fi and HL7.
Technical Specifications
| Feature | Specification |
| Model | PF680 |
| Parameter | FVC: FVC, FEV1, FEV1%, PEF, FEF25, FEF50, FEF75VC: VC, VT, IRV, ERV, IC MVV: MVV, VT, RR |
| Flow Detection Principle | Pneumotachograph |
| Volume Range | Volume: (0.5-8) LFlow: (0-14) L/s |
| Performance Standard | ATS/ERS 2005 & ISO 26783:2009 |
| Volume Accuracy | ±3% or ±0.050L (take the larger value) |
| Power Supply | 3.7 V lithium battery (rechargeable) |
| Printer | Built-in thermal printer |
| Operating Temperature | 10℃ - 40℃ |
| Operating Relative Humidity | ≤ 80% |
| Size | Spirometer: 133x82x68 mmSensor Handle: 82x59x33 mm |
| Weight | 575g (including the Flow Transducer) |
Product detail pictures:
Related Product Guide:
Our focus on should be to consolidate and enhance the quality and repair of present products, in the meantime constantly establish new products to meet unique customers' requires for High Quality for Diabetic Patient Management System - UBREATH ® Spirometer System (PF680) – e-Linkcare , The product will supply to all over the world, such as: Botswana, Boston, Ghana, With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.