Hot-selling Forced Expiratory Volume In One Second - UBREATH ® Spirometer System (PF680) – e-Linkcare

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our pursuit and corporation aim should be to "Always satisfy our consumer requirements". We carry on to build and style and design remarkable quality items for both our outdated and new clients and reach a win-win prospect for our clients at the same time as us for Glucose Blood Test , Gestational Glucose Test , Blood Sugar Level Monitor , We are confident that there will be a promising future and we hope we can have long term cooperation with customers from all over the world.
Hot-selling Forced Expiratory Volume In One Second - UBREATH ® Spirometer System (PF680) – e-Linkcare Detail:

Measurable Spirometry through Inhale & Exhale
FVC, SVC, MVV are available with 23 parameters to be calculated.
Accuracy and repeatability comply with ATS/ERS task force standardization (ISO26782:2009)
Complies with the ATS/ERS requirement for flow sensitivity down to 0.025L/s which is a vital characteristic for the diagnosis and monitoring of COPD patients.

Real-time Graphic Curve Experience
Synchronized graphs enhance users to achieve satisfied results with professional’s guidance.
Displayed three waveform parameters and remark the best performance for reference.

Portable Design
Hand-held device and easy to operation.
Automated BTPS calibration and free of environmental conditions influence.
Lightweight combines the benefits of portability.

Operate with Safety
Assured hygiene with disposable pneumotach gives NO authority to cross-contamination.
Patented design offers prevention and no daily sterilization is required.
Automated quality control and correction algorithm to minimize interference from operation.

All-in-One Service Station
Built-in printer and barcode scanner are combined in one device.
LIS/HIS connection via Wi-Fi and HL7.

Technical Specifications

Feature Specification
Model PF680
Parameter FVC: FVC, FEV1, FEV1%, PEF, FEF25, FEF50, FEF75VC: VC, VT, IRV, ERV, IC
MVV: MVV, VT, RR
Flow Detection Principle Pneumotachograph
Volume Range Volume: (0.5-8) LFlow: (0-14) L/s
Performance Standard ATS/ERS 2005 & ISO 26783:2009
Volume Accuracy ±3% or ±0.050L (take the larger value)
Power Supply 3.7 V lithium battery (rechargeable)
Printer Built-in thermal printer
Operating Temperature 10℃ - 40℃
Operating Relative Humidity ≤ 80%
Size Spirometer: 133x82x68 mmSensor Handle: 82x59x33 mm
Weight 575g (including the Flow Transducer)

Product detail pictures:

Hot-selling Forced Expiratory Volume In One Second - UBREATH ® Spirometer System (PF680) – e-Linkcare detail pictures


Related Product Guide:

Our crew through skilled training. Skilled skilled knowledge, strong sense of company, to meet the company wants of customers for Hot-selling Forced Expiratory Volume In One Second - UBREATH ® Spirometer System (PF680) – e-Linkcare , The product will supply to all over the world, such as: Netherlands, UAE, Algeria, Our advantages are our innovation, flexibility and reliability which have been built during last 20 years. We focus on providing service for our clients as a key element in strengthening our long-term relationships. The continual availability of high grade products in combination with our excellent pre- and after-sales service ensures strong competitiveness in an increasingly globalized market.
  • The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Genevieve from Azerbaijan - 2017.03.07 13:42
    We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
    5 Stars By Victor Yanushkevich from Uruguay - 2018.05.13 17:00
    Write your message here and send it to us