Manufactur standard Blood Sugar Monitor - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Adhering to the principle of "quality, service, efficiency and growth", we have gained trusts and praises from domestic and international client for Blood Sugar Test Kit , One Drop Glucometer , Type 2 Diabetes Test , We adhere to the tenet of "Services of Standardization, to Meet Customers' Demands".
Manufactur standard Blood Sugar Monitor - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare Detail:

Features:

Chronic airway inflammation is a general feature of some types of asthma, cystic fibrosis (CF), bronchopulmonary dysplasia (BPD), and chronic obstructive pulmonary disease (COPD).
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

Fractional concentration of carbon monoxide in exhaled breath (FeCO), similar to FeNO, has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs.

UBREATH Exhalation analyzer (BA810) is a medical device designed & manufactured by e-LinkCare Meditech to associate with both FeNO and FeCO testing to provide rapid, precise, quantitative measurement in order to assist with clinical diagnosis and management such as asthma and other chonic airway inflammations.

In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

ITEM Measurement Reference
FeNO50  Fixed Exhale flow level of 50ml/s 5-15ppb
FeNO200  Fixed Exhale flow level of 200ml/s <10 ppb

In the meantime, BA200 also provides data for the following parameters

ITEM Measurement Reference
CaNO Concentration of NO in the gas phase of the alveolar <5 ppb
FnNO Nasal nitric oxide 250-500 ppb
FeCO Fractional concentration of carbon monoxide in exhaled breath 1-4ppm>6 ppm (if smoking)

Product detail pictures:

Manufactur standard Blood Sugar Monitor - UBREATH ® Exhalation analyzer (BA200)  – e-Linkcare detail pictures


Related Product Guide:

We're proud from the higher client fulfillment and wide acceptance due to our persistent pursuit of high quality both on product and service for Manufactur standard Blood Sugar Monitor - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare , The product will supply to all over the world, such as: Lithuania, Bahrain, Doha, We have a dedicated and aggressive sales team, and many branches, catering to our customers. We are looking for long-term business partnerships, and ensure our suppliers that they will definitely benefit in both short and long run.
  • Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Freda from Kenya - 2018.06.18 17:25
    On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Johnny from Gambia - 2017.09.29 11:19
    Write your message here and send it to us