New Delivery for Blood Sugar 77 - UBREATH ® Spirometer System (PF680) – e-Linkcare

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We also provide item sourcing and flight consolidation solutions. We have now our very own manufacturing facility and sourcing place of work. We could provide you with nearly every kind of merchandise associated to our merchandise variety for Best Glucose Meter 2019 , Prediabetes Blood Sugar Level , Best Glucometer In World , Warmly welcome to cooperate and develop with us! we will continue to provide product with high quality and competitive price.
New Delivery for Blood Sugar 77 - UBREATH ® Spirometer System (PF680) – e-Linkcare Detail:

Measurable Spirometry through Inhale & Exhale
FVC, SVC, MVV are available with 23 parameters to be calculated.
Accuracy and repeatability comply with ATS/ERS task force standardization (ISO26782:2009)
Complies with the ATS/ERS requirement for flow sensitivity down to 0.025L/s which is a vital characteristic for the diagnosis and monitoring of COPD patients.

Real-time Graphic Curve Experience
Synchronized graphs enhance users to achieve satisfied results with professional’s guidance.
Displayed three waveform parameters and remark the best performance for reference.

Portable Design
Hand-held device and easy to operation.
Automated BTPS calibration and free of environmental conditions influence.
Lightweight combines the benefits of portability.

Operate with Safety
Assured hygiene with disposable pneumotach gives NO authority to cross-contamination.
Patented design offers prevention and no daily sterilization is required.
Automated quality control and correction algorithm to minimize interference from operation.

All-in-One Service Station
Built-in printer and barcode scanner are combined in one device.
LIS/HIS connection via Wi-Fi and HL7.

Technical Specifications

Feature Specification
Model PF680
Parameter FVC: FVC, FEV1, FEV1%, PEF, FEF25, FEF50, FEF75VC: VC, VT, IRV, ERV, IC
MVV: MVV, VT, RR
Flow Detection Principle Pneumotachograph
Volume Range Volume: (0.5-8) LFlow: (0-14) L/s
Performance Standard ATS/ERS 2005 & ISO 26783:2009
Volume Accuracy ±3% or ±0.050L (take the larger value)
Power Supply 3.7 V lithium battery (rechargeable)
Printer Built-in thermal printer
Operating Temperature 10℃ - 40℃
Operating Relative Humidity ≤ 80%
Size Spirometer: 133x82x68 mmSensor Handle: 82x59x33 mm
Weight 575g (including the Flow Transducer)

Product detail pictures:

New Delivery for Blood Sugar 77 - UBREATH ® Spirometer System (PF680) – e-Linkcare detail pictures


Related Product Guide:

We retain bettering and perfecting our merchandise and service. At the same time, we do the job actively to do research and improvement for New Delivery for Blood Sugar 77 - UBREATH ® Spirometer System (PF680) – e-Linkcare , The product will supply to all over the world, such as: Turkey, Jordan, Nigeria, Wide selection and fast delivery for you! Our philosophy: Good quality, great service, keep improving. We are looking forward that more and more oversea friends join in our family for further development near the future!
  • The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Pearl Permewan from Australia - 2018.12.10 19:03
    The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Elsie from Anguilla - 2018.09.23 18:44
    Write your message here and send it to us