One of Hottest for Steam Nebuliser - ACCUGENCE ® Multi-Monitoring System (PM 900) – e-Linkcare
One of Hottest for Steam Nebuliser - ACCUGENCE ® Multi-Monitoring System (PM 900) – e-Linkcare Detail:
Advanced Features

Specification
|
Feature |
Specification |
|
Parameter |
Blood Glucose, Blood β-Ketone, and Blood Uric Acid |
|
Measurement Range |
Blood Glucose: 0.6 – 33.3 mmol/L (10 – 600 mg/dL) |
|
Blood β-Ketone: 0.0 – 8.0 mmol/L |
|
|
Uric Acid: 3.0 – 20.0 mg/dL (179 – 1190 μmol/L) |
|
|
Hematocrit Range |
Blood Glucose and β-Ketone: 15% – 70 % |
|
Uric Acid: 25% – 60% |
|
|
Sample |
When testing β-Ketone, Uric Acid or Blood glucose with Glucose Dehydrogenase FAD-Dependent, use fresh capillary whole blood and venous Blood samples; |
|
When testing Blood glucose with Glucose Oxidase: use fresh capillary whole blood |
|
|
Minimum Sample Size |
Blood Glucose: 0.7 μL |
|
Blood β-Ketone: 0.9 μL |
|
|
Blood Uric Acid: 1.0 μL |
|
|
Test Time |
Blood Glucose: 5 seconds |
|
Blood β-Ketone: 5 seconds |
|
|
Blood Uric Acid: 15 seconds |
|
|
Units of Measure |
Blood Glucose:The meter is preset to either millimole per liter (mmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
|
Blood β-Ketone: The meter is preset to millimole per liter (mmol/L) |
|
|
Blood Uric Acid:The meter is preset to either micromoles per liter (μmol/L) or milligrams per deciliter (mg/dL) depending on the standard of your country. |
|
|
Memory |
Blood Glucose: 500 tests (GOD + GDH) |
|
Blood β-Ketone: 100 tests |
|
|
Blood Uric Acid: 100 tests |
|
|
Automatic Shutoff |
2 minutes |
|
Meter Size |
86 mm × 52 mm × 18 mm |
|
On/Off Source |
Two CR 2032 3.0V coin cell batteries |
|
Battery Life |
Around 1000 tests |
|
Display Size |
32 mm × 40 mm |
|
Weight |
53 g (with battery installed) |
|
Operating Temperature |
Glucose and Ketone: 5 – 45 ºC (41 – 113ºF) |
|
Uric Acid: 10 – 40 ºC (50 – 104ºF) |
|
|
Operating Relative Humidity |
10 – 90% (non-condensing) |
|
Operating Altitude |
0 – 10000 feet (0 – 3048 meters) |
Product detail pictures:
Related Product Guide:
Our company sticks to the principle of "Quality is the life of the company, and reputation is the soul of it" for One of Hottest for Steam Nebuliser - ACCUGENCE ® Multi-Monitoring System (PM 900) – e-Linkcare , The product will supply to all over the world, such as: Indonesia, The Swiss, Suriname, Our company's main products are widely used all over the world; 80% of our products exported to the United States, Japan, Europe and other markets. All stuff sincerely welcome guests come to visit our factory.
Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.