abide by the contract", conforms towards the market requirement, joins during the market competition by its good quality likewise as provides additional comprehensive and great services for customers to let them turn out to be big winner. The pursue of your enterprise, is the clients' fulfillment for Morning Blood Sugar , Glucose Testing , Non Fasting Blood Glucose , We welcome new and previous clients from all walks of lifestyle to get in touch with us for long term business relationships and mutual accomplishment!
Popular Design for Glucometer Reading Accuracy - UBREATH ® Spirometer System (PF680) – e-Linkcare Detail:

Measurable Spirometry through Inhale & Exhale
FVC, SVC, MVV are available with 23 parameters to be calculated.
Accuracy and repeatability comply with ATS/ERS task force standardization (ISO26782:2009)
Complies with the ATS/ERS requirement for flow sensitivity down to 0.025L/s which is a vital characteristic for the diagnosis and monitoring of COPD patients.

Real-time Graphic Curve Experience
Synchronized graphs enhance users to achieve satisfied results with professional’s guidance.
Displayed three waveform parameters and remark the best performance for reference.

Portable Design
Hand-held device and easy to operation.
Automated BTPS calibration and free of environmental conditions influence.
Lightweight combines the benefits of portability.

Operate with Safety
Assured hygiene with disposable pneumotach gives NO authority to cross-contamination.
Patented design offers prevention and no daily sterilization is required.
Automated quality control and correction algorithm to minimize interference from operation.

All-in-One Service Station
Built-in printer and barcode scanner are combined in one device.
LIS/HIS connection via Wi-Fi and HL7.

Technical Specifications

Feature Specification
Model PF680
Parameter FVC: FVC, FEV1, FEV1%, PEF, FEF25, FEF50, FEF75VC: VC, VT, IRV, ERV, IC
MVV: MVV, VT, RR
Flow Detection Principle Pneumotachograph
Volume Range Volume: (0.5-8) LFlow: (0-14) L/s
Performance Standard ATS/ERS 2005 & ISO 26783:2009
Volume Accuracy ±3% or ±0.050L (take the larger value)
Power Supply 3.7 V lithium battery (rechargeable)
Printer Built-in thermal printer
Operating Temperature 10℃ - 40℃
Operating Relative Humidity ≤ 80%
Size Spirometer: 133x82x68 mmSensor Handle: 82x59x33 mm
Weight 575g (including the Flow Transducer)

Product detail pictures:

Popular Design for Glucometer Reading Accuracy - UBREATH ® Spirometer System (PF680) – e-Linkcare detail pictures


Related Product Guide:

We have been also concentrating on enhancing the things management and QC method so that we could preserve terrific edge inside the fiercely-competitive enterprise for Popular Design for Glucometer Reading Accuracy - UBREATH ® Spirometer System (PF680) – e-Linkcare , The product will supply to all over the world, such as: Eindhoven, Rotterdam, Riyadh, With well educated, innovative and energetic staff, we are responsible for all elements of research, design, manufacture, sale and distribution. By studying and developing new techniques, we are not only following but also leading fashion industry. We listen attentively to the feedback from our customers and provide instant replies. You will instantly feel our professional and attentive service.
  • Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Flora from Nepal - 2018.11.11 19:52
    The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Mandy from United Arab Emirates - 2018.11.06 10:04
    Write your message here and send it to us