Professional Design Continuous Blood Glucose Monitor - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We've been convinced that with joint efforts, the enterprise between us will bring us mutual benefits. We could guarantee you item excellent and aggressive price tag for Low Blood Sugar Test , 149 Blood Sugar , Serum Glucose , We are looking forward to forming successful business relationship with new clients in the near future!
Professional Design Continuous Blood Glucose Monitor - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare Detail:

Features:

Chronic airway inflammation is a general feature of some types of asthma, cystic fibrosis (CF), bronchopulmonary dysplasia (BPD), and chronic obstructive pulmonary disease (COPD).
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

Fractional concentration of carbon monoxide in exhaled breath (FeCO), similar to FeNO, has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs.

UBREATH Exhalation analyzer (BA810) is a medical device designed & manufactured by e-LinkCare Meditech to associate with both FeNO and FeCO testing to provide rapid, precise, quantitative measurement in order to assist with clinical diagnosis and management such as asthma and other chonic airway inflammations.

In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

ITEM Measurement Reference
FeNO50  Fixed Exhale flow level of 50ml/s 5-15ppb
FeNO200  Fixed Exhale flow level of 200ml/s <10 ppb

In the meantime, BA200 also provides data for the following parameters

ITEM Measurement Reference
CaNO Concentration of NO in the gas phase of the alveolar <5 ppb
FnNO Nasal nitric oxide 250-500 ppb
FeCO Fractional concentration of carbon monoxide in exhaled breath 1-4ppm>6 ppm (if smoking)

Product detail pictures:

Professional Design Continuous Blood Glucose Monitor - UBREATH ® Exhalation analyzer (BA200)  – e-Linkcare detail pictures


Related Product Guide:

carry on to further improve, to guarantee merchandise high-quality in line with market and buyer standard necessities. Our organization has a top quality assurance procedure have already been established for Professional Design Continuous Blood Glucose Monitor - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare , The product will supply to all over the world, such as: Kyrgyzstan, Egypt, Colombia, We now have established long-term, stable and good business relationships with many manufacturers and wholesalers around the world. Currently, we've been looking forward to even greater cooperation with overseas customers based on mutual benefits. You should feel free to contact us for more details.
  • Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
    5 Stars By Chloe from Malawi - 2018.11.02 11:11
    In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By Gloria from Montpellier - 2017.12.19 11:10
    Write your message here and send it to us