Super Purchasing for God Pod Principle - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With advanced technologies and facilities, strict quality control, reasonable price, superior service and close co-operation with customers, we are devoted to providing the best value for our customers for One Drop Glucose Meter , Fasting Low Blood Sugar , Blood Sugar Monitor , Our company warmly welcome friends from all over the world to visit, investigate and negotiate business.
Super Purchasing for God Pod Principle - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare Detail:

Features:

Chronic airway inflammation is a general feature of some types of asthma, cystic fibrosis (CF), bronchopulmonary dysplasia (BPD), and chronic obstructive pulmonary disease (COPD).
In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

Fractional concentration of carbon monoxide in exhaled breath (FeCO), similar to FeNO, has been evaluated as a candidate breath biomarker of pathophysiological states, including smoking status, and inflammatory diseases of the lung and other organs.

UBREATH Exhalation analyzer (BA810) is a medical device designed & manufactured by e-LinkCare Meditech to associate with both FeNO and FeCO testing to provide rapid, precise, quantitative measurement in order to assist with clinical diagnosis and management such as asthma and other chonic airway inflammations.

In today’s world, a noninvasive,simple, repeatable, quick, convenient, and relatively low cost test called Fractional exhaled nitric oxide (FeNO), often plays a role to help identify airway inflammation, and thereby support a diagnosis of asthma when there is diagnostic uncertainty.

ITEM Measurement Reference
FeNO50  Fixed Exhale flow level of 50ml/s 5-15ppb
FeNO200  Fixed Exhale flow level of 200ml/s <10 ppb

In the meantime, BA200 also provides data for the following parameters

ITEM Measurement Reference
CaNO Concentration of NO in the gas phase of the alveolar <5 ppb
FnNO Nasal nitric oxide 250-500 ppb
FeCO Fractional concentration of carbon monoxide in exhaled breath 1-4ppm>6 ppm (if smoking)

Product detail pictures:

Super Purchasing for God Pod Principle - UBREATH ® Exhalation analyzer (BA200)  – e-Linkcare detail pictures


Related Product Guide:

It really is our obligation to satisfy your requirements and efficiently serve you. Your fulfillment is our greatest reward. We're hunting forward to your check out for joint development for Super Purchasing for God Pod Principle - UBREATH ® Exhalation analyzer (BA200) – e-Linkcare , The product will supply to all over the world, such as: Singapore, Kazakhstan, Jamaica, With the superior and exceptional service, we are well developed along with our customers. Expertise and know-how ensure that we are always enjoying the trust from our customers in our business activities. "Quality", "honesty" and "service" is our principle. Our loyalty and commitments remain respectfully at your service. Contact Us Today For further information, contact us now.
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Myra from Islamabad - 2018.09.12 17:18
    High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
    5 Stars By Lynn from Colombia - 2018.03.03 13:09
    Write your message here and send it to us